Шкаф управления насосом исполнения М

WP_Post Object ( [ID] => 10793 [post_author] => 116 [post_date] => 2021-02-20 12:53:08 [post_date_gmt] => 2021-02-20 08:53:08 [post_content] => [post_title] => Шкаф управления насосом исполнения М [post_excerpt] => [post_status] => publish [comment_status] => closed [ping_status] => closed [post_password] => [post_name] => shkaf-upravleniya-nasosom-ispolneniya-m [to_ping] => [pinged] => [post_modified] => 2021-02-24 10:44:26 [post_modified_gmt] => 2021-02-24 06:44:26 [post_content_filtered] => [post_parent] => 0 [guid] => http://plazma-t.ru/?post_type=device&p=10793 [menu_order] => 0 [post_type] => device [post_mime_type] => [comment_count] => 0 [filter] => raw ) Array ( [_edit_lock] => Array ( [0] => 1614149004:116 ) [_edit_last] => Array ( [0] => 116 ) [slide_template] => Array ( [0] => default ) [type_pr] => Array ( [0] => 0 ) [_type_pr] => Array ( [0] => field_5dfb521bfd66b ) [short] => Array ( [0] => ШУН-М ) [description] => Array ( [0] => ШУН-М предназначен для управления одно/трехфазным электродвигателем насоса систем водяного, пенного пожаротушения и противопожарного водопровода в режиме «Местный пуск» с лицевой панели ШУН-М или по сигналам любого модуля управления в режиме «Автоматический пуск» с отображением состояния насоса при помощи световой индикации и с передачей сигналов состояния на модуль управления. Серия силовых шкафов ШУН-М рассчитана на различную мощность, а также предусматривает два способа пуска: прямой и мягкий (с использование устройства плавного пуска – УПП). ШУН-М работает с любыми типами пожарных приборов управления и управляется как через выход типа «сухой контакт», так и через потенциальный выход 24В/220В. Наличие встроенного источника питания на 24В. ШУН-М имеет пространство для монтажа модуля управления внутри шкафа. Согласно ГОСТ 53325-2012 обеспечивает контроль исправности линий питания до электродвигателя насоса. Аппаратура коммутации трех производителей: DEKraft, Schneider Electric, ABB (в зависимости от исполнения). Степень защиты оболочки – IP31 или IP54 (в зависимости от исполнения). ШУН-М сертифицирован на соответствие требованиям ТР ТС. Исполнения ШУН-М:
  • ШУН-М/х/IP31 – прямой пуск, комплектация DEK, IP31
  • ШУН-М/х/IP54 – прямой пуск, комплектация DEK, IP54
  • ШУН-М/х/IP54/SE – прямой пуск, комплектация SE, IP54
  • ШУН-М/х/IP54/ABB – прямой пуск, комплектация ABB, IP54 где х – мощность насосов (0,37 – 110 кВт).
  • ШУН-М/х/M/IP31 – прямой пуск, комплектация DEK, IP31
  • ШУН-М/х/M/IP54 – прямой пуск, комплектация DEK, IP54
  • ШУН-М/х/M/IP54/SE – прямой пуск, комплектация SE, IP54
  • ШУН-М/х/M/IP54/ABB – прямой пуск, комплектация ABB, IP54 где х – мощность насосов (5,5 – 250 кВт).
) [advdesc] => Array ( [0] => ) [tth] => Array ( [0] => ) [_pods_razdel] => Array ( [0] => 2 ) [numorder] => Array ( [0] => 5 ) [tth_tabl] => Array ( [0] =>
Напряжение питания шкафа: при управлении трехфазным электродвигателем ~380В, 50 Гц
при управлении однофазным электродвигателем ~220В, 50 Гц
Потребляемая мощность в дежурном режиме до 5 ВА
Способ пуска электродвигателя: Прямой пуск УПП
Линейка мощностей 0,37кВт/380 или 0,18кВт/220* + +
0,55кВт/380 или 0,25кВт/220* + +
0,75кВт/380 или 0,37кВт/220* + +
1,1кВт/380В или 0,55кВт/220* + +
1,5кВт/380В или 0,75кВт/220* + +
2,2кВт/380В или 1,1кВт/220В* + +
3,0кВт/380В или 1,5кВт/220В* + +
4,0кВт/380В или 2,2кВт/220В* + +
5,5 кВт/380В + +
7,5 кВт/380В + +
11,0 кВт/380В + +
15,0 кВт/380В + +
18,5 кВт/380В + +
22,0 кВт/380В + +
30,0 кВт/380В + +
37,0 кВт/380В + +
45,0 кВт/380В + +
55,0 кВт/380В + +
75,0 кВт/380В + +
90,0 кВт/380В + +
110 кВт/380В + +
132 кВт/380В +
160 кВт/380В +
200 кВт/380В +
250 кВт/380В +
Мощность электропитания модуля управления ±24В до 14,0 Вт
≈220В до 20 ВА
Автоматический контроль наличия питания на электровводе и включенного состояния вводного автомата формирование сигнала «Авария» при отсутствии питания хотя бы по одной из фаз электроввода или отключении вводного автомата
силовых цепей до электродвигателя до 3-х цепей на обрыв*
времени пуска насоса от 5 до 75 сек
исправности всех шлейфов на обрыв и КЗ*
Работы пусковой аппаратуры есть
Сигнальные реле Авария «Сухие контакты».
Автоматика отключена Отсутств.сигн.- контакт разомкнут
Насос включен Наличие сигнала – контакт замкнут
Органы управления Переключатель режима работы с ключом «Пуск»-«Стоп»-«Авт.» «Местный пуск», «Отключение», «Автоматический пуск»
Дополнительная индикация: «Авария» Включение встроенных индикаторов при наличии сигнала на входах LED
«Автоматика отключена»
Габариты места для установки модуля управления внутри шкафа (ВхШхГ) не менее 140х180х140 мм
Средний срок службы не менее 10 лет
Диапазон рабочих температур от -10°C до +55°C
Допустимая относительная влажность до 93% при 40°C
Степень защиты оболочки IP31 или IP54
Климатическое исполнение УХЛ 3.1
Средний срок службы не менее 10 лет
Диапазон рабочих температур от -10°C до +55°C
Условия для шкафов с устройствами плавного пуска (УПП) Рабочая температура от 0 до +40°C. Высота над уровнем моря ≤ 1000 м.
Для УПП не более 10 пусков в час.
Допустимая относительная влажность до 93% при 40°C
Степень защиты оболочки IP31 или IP54
Климатическое исполнение УХЛ 3.1.
Производитель аппаратуры коммутации DEKraft, ABB или Schneider Electric
) [hide_tech] => Array ( [0] => 0 ) [hide_down] => Array ( [0] => 0 ) [razdel_adr] => Array ( [0] => device ) [contact_form_code] => Array ( [0] => ) [_pods_devicedocs] => Array ( [0] => a:15:{i:0;i:7527;i:1;i:3697;i:2;i:10801;i:3;i:2839;i:4;i:3245;i:5;i:7988;i:6;i:3539;i:7;i:8397;i:8;i:10753;i:9;i:10783;i:10;i:3545;i:11;i:3547;i:12;i:3549;i:13;i:3551;i:14;i:3543;} ) [_pods_images] => Array ( [0] => a:7:{i:0;i:10794;i:1;i:10795;i:2;i:10796;i:3;i:10797;i:4;i:10798;i:5;i:10799;i:6;i:10800;} ) [_relevanssi_pin] => Array ( [0] => ) [_relevanssi_unpin] => Array ( [0] => ) [razdel] => Array ( [0] => 2 ) [devicedocs] => Array ( [0] => 7527 [1] => 3697 [2] => 10801 [3] => 2839 [4] => 3245 [5] => 7988 [6] => 3539 [7] => 8397 [8] => 10753 [9] => 10783 [10] => 3545 [11] => 3547 [12] => 3549 [13] => 3551 [14] => 3543 ) [images] => Array ( [0] => 10794 [1] => 10795 [2] => 10796 [3] => 10797 [4] => 10798 [5] => 10799 [6] => 10800 ) )


смотреть все изображения

ШУН-М
Шкаф управления насосом исполнения М

ШУН-М предназначен для управления одно/трехфазным электродвигателем насоса систем водяного, пенного пожаротушения и противопожарного водопровода в режиме «Местный пуск» с лицевой панели ШУН-М или по сигналам любого модуля управления в режиме «Автоматический пуск» с отображением состояния насоса при помощи световой индикации и с передачей сигналов состояния на модуль управления.

Серия силовых шкафов ШУН-М рассчитана на различную мощность, а также предусматривает два способа пуска: прямой и мягкий (с использование устройства плавного пуска – УПП).

ШУН-М работает с любыми типами пожарных приборов управления и управляется как через выход типа «сухой контакт», так и через потенциальный выход 24В/220В.

Наличие встроенного источника питания на 24В.

ШУН-М имеет пространство для монтажа модуля управления внутри шкафа.

Согласно ГОСТ 53325-2012 обеспечивает контроль исправности линий питания до электродвигателя насоса.

Аппаратура коммутации трех производителей: DEKraft, Schneider Electric, ABB (в зависимости от исполнения).

Степень защиты оболочки – IP31 или IP54 (в зависимости от исполнения).

ШУН-М сертифицирован на соответствие требованиям ТР ТС.

Исполнения ШУН-М:

  • ШУН-М/х/IP31 – прямой пуск, комплектация DEK, IP31
  • ШУН-М/х/IP54 – прямой пуск, комплектация DEK, IP54
  • ШУН-М/х/IP54/SE – прямой пуск, комплектация SE, IP54
  • ШУН-М/х/IP54/ABB – прямой пуск, комплектация ABB, IP54
    где х – мощность насосов (0,37 – 110 кВт).
  • ШУН-М/х/M/IP31 – прямой пуск, комплектация DEK, IP31
  • ШУН-М/х/M/IP54 – прямой пуск, комплектация DEK, IP54
  • ШУН-М/х/M/IP54/SE – прямой пуск, комплектация SE, IP54
  • ШУН-М/х/M/IP54/ABB – прямой пуск, комплектация ABB, IP54
    где х – мощность насосов (5,5 – 250 кВт).
Напряжение питания шкафа: при управлении трехфазным электродвигателем ~380В, 50 Гц
при управлении однофазным электродвигателем ~220В, 50 Гц
Потребляемая мощность в дежурном режиме до 5 ВА
Способ пуска электродвигателя: Прямой пуск УПП
Линейка мощностей 0,37кВт/380 или 0,18кВт/220* + +
0,55кВт/380 или 0,25кВт/220* + +
0,75кВт/380 или 0,37кВт/220* + +
1,1кВт/380В или 0,55кВт/220* + +
1,5кВт/380В или 0,75кВт/220* + +
2,2кВт/380В или 1,1кВт/220В* + +
3,0кВт/380В или 1,5кВт/220В* + +
4,0кВт/380В или 2,2кВт/220В* + +
5,5 кВт/380В + +
7,5 кВт/380В + +
11,0 кВт/380В + +
15,0 кВт/380В + +
18,5 кВт/380В + +
22,0 кВт/380В + +
30,0 кВт/380В + +
37,0 кВт/380В + +
45,0 кВт/380В + +
55,0 кВт/380В + +
75,0 кВт/380В + +
90,0 кВт/380В + +
110 кВт/380В + +
132 кВт/380В +
160 кВт/380В +
200 кВт/380В +
250 кВт/380В +
Мощность электропитания модуля управления ±24В до 14,0 Вт
≈220В до 20 ВА
Автоматический контроль наличия питания на электровводе и включенного состояния вводного автомата формирование сигнала «Авария» при отсутствии питания хотя бы по одной из фаз электроввода или отключении вводного автомата
силовых цепей до электродвигателя до 3-х цепей на обрыв*
времени пуска насоса от 5 до 75 сек
исправности всех шлейфов на обрыв и КЗ*
Работы пусковой аппаратуры есть
Сигнальные реле Авария «Сухие контакты».
Автоматика отключена Отсутств.сигн.- контакт разомкнут
Насос включен Наличие сигнала – контакт замкнут
Органы управления Переключатель режима работы с ключом «Пуск»-«Стоп»-«Авт.» «Местный пуск», «Отключение», «Автоматический пуск»
Дополнительная индикация: «Авария» Включение встроенных индикаторов при наличии сигнала на входах LED
«Автоматика отключена»
Габариты места для установки модуля управления внутри шкафа (ВхШхГ) не менее 140х180х140 мм
Средний срок службы не менее 10 лет
Диапазон рабочих температур от -10°C до +55°C
Допустимая относительная влажность до 93% при 40°C
Степень защиты оболочки IP31 или IP54
Климатическое исполнение УХЛ 3.1
Средний срок службы не менее 10 лет
Диапазон рабочих температур от -10°C до +55°C
Условия для шкафов с устройствами плавного пуска (УПП) Рабочая температура от 0 до +40°C. Высота над уровнем моря ≤ 1000 м.
Для УПП не более 10 пусков в час.
Допустимая относительная влажность до 93% при 40°C
Степень защиты оболочки IP31 или IP54
Климатическое исполнение УХЛ 3.1.
Производитель аппаратуры коммутации DEKraft, ABB или Schneider Electric


Поиск документов