МС322-24 Модуль контроля и управления 4-х канальный

WP_Post Object ( [ID] => 10049 [post_author] => 7 [post_date] => 2020-05-20 17:59:33 [post_date_gmt] => 2020-05-20 13:59:33 [post_content] => МС322-24    [post_title] => МС322-24 Модуль контроля и управления 4-х канальный [post_excerpt] => [post_status] => publish [comment_status] => closed [ping_status] => closed [post_password] => [post_name] => ms322-24-modul-kontrolya-i-upravleniya-4-h-kanalnyj [to_ping] => [pinged] => [post_modified] => 2020-12-21 16:15:47 [post_modified_gmt] => 2020-12-21 12:15:47 [post_content_filtered] => [post_parent] => 0 [guid] => http://plazma-t.ru/?post_type=device&p=10049 [menu_order] => 0 [post_type] => device [post_mime_type] => [comment_count] => 0 [filter] => raw ) Array ( [_edit_lock] => Array ( [0] => 1608553774:116 ) [_edit_last] => Array ( [0] => 116 ) [slide_template] => Array ( [0] => default ) [short] => Array ( [0] => МС322-24 ) [description] => Array ( [0] => Модуль МС322-24 применяется в системах пожарной сигнализации и системах противопожарной защиты, предназначен для:
  • контроля двух шлейфов (занимают два адреса) для подключения безадресных пожарных извещателей или «сухой контакт» (нормально-замкнутых/нормально-разомкнутых) и двух технологических входов (не имеют адреса) для подключения «сухих контактов» (нормально-замкнутых/нормально-разомкнутых) с контролем исправности входов;
  • управления двумя нереверсивными устройствами или одним реверсивным устройством с напряжением питания =12­­÷24В DC по командам от прибора ПАС300 с контролем исправности цепей управления на обрыв во всех состояниях и на КЗ в дежурном режиме.
МС322-24 имеет встроенные трехцветные светодиодные индикаторы для расширенного отображения состояния всех входов, устройств, а также самого модуля. МС322-24 имеет встроенный изолятор короткого замыкания в интерфейсе С300. МС322-24 позволяет управлять режимом работы световых табло по алгоритму:
  • Дежурный режим – горит непрерывно;
  • Режим Пожар – мигает с программируемой длительностью.
Основные функции: Модуль обеспечивает:
  • Подключение и контроль состояния двух универсальных сигнальных шлейфов (пожарный тип1/тип2/тип3, НРК, НЗК) с контролем исправности на обрыв и короткое замыкание, а также передачу сигналов на прибор ПАС300. Для шлейфов предусмотрена возможность программирования соответствующих сигналов (Пожар, Внимание, Авария, нет сигнала), которые будут формироваться в системе С300 при срабатывании входа. Каждый сигнальный шлейф имеет адрес и может быть установлен в любую из 40 зон контроля в ПАС300 (по умолчанию зона 1);
  • Подключение и контроль состояния двух технологических нормально-замкнутых и/или нормально-разомкнутых входов типа «сухой контакт» с контролем исправности на обрыв и короткое замыкание и их передачу на прибор ПАС300. Для входов предусмотрена возможность программирования соответствующих сигналов (Авария источника питания, Авария устройства, Автоматика отключена, Ручной Пуск), которые будут формироваться в системе С300 при срабатывании входа. Технологические входы не имеют адресов и привязаны к адресу соответствующего устройства или входа питания;
  • Подключение двух нереверсивных исполнительных устройств или одного реверсивного устройства напряжением питания 12÷24В DС с контролем исправности цепей управления на обрыв во всех режимах и короткое замыкание в дежурном режиме;
  • По каждому выходу обеспечивается ток:
    • до 1 А импульсно или непрерывно любое время
    • до 5 А импульс длительностью до 3 сек или
    • до 3 импульсов длительностью 1 сек.
  • Каждый выход модуля имеет встроенную самовосстанавливающуюся защиту от короткого замыкания. При обнаружении короткого замыкания запуск устройства произведен не будет.
Полный контроль работоспособности обеспечивается как на физическом уровне (функция самотестирования в модуле), так и на программном уровне (постоянный опрос ПАС300). Модуль занимает 4 адреса в адресном пространстве С300. Интерфейсная часть МС322-24 питается от прибора ПАС300. Электронное программирование адреса (0 – заводская установка). Восемь встроенных трехцветных светодиодных индикаторов помимо состояния сигнальных шлейфов (Сработка, Двойная Сработка и Дежурный режим) обеспечивают расширенную индикацию состояний самого модуля (неисправность, дублирование адресов, нулевой адрес, нет в базе ПАС300 и т.д.), а также состояние подключенного оборудования, что значительно упрощает процессы настройки и обслуживания системы С300 в целом. Для каждого нереверсивного устройства помимо включения/отключения и возможности задания задержки пуска и остановки, предусмотрена возможность контролировать выход устройства на режим (поле Адрес подтверждающего датчика), а также опции по контролю цепи управления устройства (контроль на обрыв, контроль на КЗ, контроль на обрыв и КЗ, не контролировать) и состояние выхода в дежурном режиме:
  • Опция «Инверсный выход» не активна - выход выключен;
  • Опция «Инверсный выход» активна - выход включен
  ) [advdesc] => Array ( [0] => Для реверсивного устройства помимо возможности задания задержки пуска и остановки предусмотрена возможность выбора дежурного состояния (Реверсивный нормально открытый, Реверсивный нормально закрытый), а также опции по контролю цепи управления устройства (контроль на обрыв, контроль на КЗ, контроль на обрыв и КЗ, не контролировать). Для каждого устройства можно запрограммировать следующие команды:
  • «Пуск», «ПускУ12» - включение устройства по истечении времени задержки на пуск
  • «½ Пуск» - включение устройства при поступлении двух и более команд «½ Пуск»
  • «Пуск с блокировкой» - включение устройства, если отсутствует сигнал блокировки
  • «Стоп» - выключение устройства по истечении времени задержки на останов
  • «½ Стоп» - выключение устройства при поступлении двух и более команд «½ Стоп»
  • «Отключить автоматику» - перевод устройства в режим «Автоматика устройства отключена»
  • «Включить автоматику» - отключение режима «Автоматика устройства отключена»
В качестве условий для формирования команд может использоваться срабатывание:
  • В любой из 40 зон данного ПАС300 или любого из 24 приборов ПАС300, объединённых в сеть
  • Любого шлейфа любого из приборов управления ПУ/ПУМ/ПУ-PL, объединённых в сеть
  • В любой из 64 групп ЦПИ, в каждую из которых можно добавлять зоны ПАС и/или шлейфы ПУ/ПУМ/ПУ-PL
) [tth] => Array ( [0] => ) [_pods_razdel] => Array ( [0] => 12 ) [numorder] => Array ( [0] => 4 ) [tth_tabl] => Array ( [0] =>

Основные технические характеристики

Шлейфы Количество 2
Электропитание из вещателей 12÷27В, зависит от схемы подключения, нагрузки на шлейф
Действующее значение пульсаций не более 20 мВ
Ограничение тока через сработавший извещатель 20 мА
Сброс извещателей путем снятия напряжения питания на 10 секунд
Время интеграции шлейфов 300 мс
Контроль исправности шлейфов на обрыв и короткое замыкание
Тенхнологические входы Количество 2
Напряжение входов 3,3 В
Контроль исправности на обрыв и короткое замыкание
Максимальная длина линии 100 м
Назначение входов - авария питания; - авария устройства 1 или 2; - вкл/откл автоматику устройства 1 или 2; - ручной пуск/стоп устройства 1 или 2.
Устройства Количество управляемых устройств 2 независимых или 1 реверсивное
Напряжение для устройств равно напряжению электропитания модуля
Ток контроля нагрузки 10 мА
Параметры каждого выхода 28 В/1,0 A – 28 Вт непрерывно, 28 В/5,0 А – 140 Вт до 3 сек
Контроль исправности цепей на обрыв и короткое замыкание во всех состояниях
Ток контроля исправности цепей не более 1,5 мА
Электропитание модуля 2 входа: =11,0÷28,4 В (≤60 Вт)
Интерфейс С300 Электропитание интерфейсной части от ПАС300 по интерфейсу С300
Напряжение интерфейса С300 от 11,5 до 28,0 В
Количество адресов в протоколе С300 4
Потребляемый ток от интерфейса не более 1,0 мА
Гальваническая развязка интерфейса есть
Изолятор короткого замыкания есть
Корпус Цвет корпуса светло-серый (RAL9002)
Масса, грамм не более 190
Габариты (ШхВхГ) 156х107х33 мм
Степень защиты оболочкой IP20
Крепление На саморезы или на DIN-рейку
Диапазон рабочих температур от минус 40 до +60°С
Допустимая относительная влажность до 93% при +40 °С
Температура транспортировки и хранения от минус 50 до +50°С
Средний срок службы не менее 10 лет
Датчик вскрытия корпуса есть
) [hide_tech] => Array ( [0] => 0 ) [hide_down] => Array ( [0] => 0 ) [razdel_adr] => Array ( [0] => device ) [contact_form_code] => Array ( [0] => ) [type_pr] => Array ( [0] => 0 ) [_type_pr] => Array ( [0] => field_5dfb521bfd66b ) [_pods_images] => Array ( [0] => a:1:{i:0;i:10528;} ) [_pods_devicedocs] => Array ( [0] => a:14:{i:0;i:3697;i:1;i:8922;i:2;i:3245;i:3;i:3308;i:4;i:7527;i:5;i:7854;i:6;i:10165;i:7;i:10610;i:8;i:10613;i:9;i:7592;i:10;i:9697;i:11;i:9696;i:12;i:10753;i:13;i:5420;} ) [_relevanssi_pin] => Array ( [0] => ) [_relevanssi_unpin] => Array ( [0] => ) [razdel] => Array ( [0] => 12 ) [images] => Array ( [0] => 10528 ) [devicedocs] => Array ( [0] => 3697 [1] => 8922 [2] => 3245 [3] => 3308 [4] => 7527 [5] => 7854 [6] => 10165 [7] => 10610 [8] => 10613 [9] => 7592 [10] => 9697 [11] => 9696 [12] => 10753 [13] => 5420 ) )


смотреть все изображения

МС322-24
МС322-24 Модуль контроля и управления 4-х канальный

Модуль МС322-24 применяется в системах пожарной сигнализации и системах противопожарной защиты, предназначен для:

  • контроля двух шлейфов (занимают два адреса) для подключения безадресных пожарных извещателей или «сухой контакт» (нормально-замкнутых/нормально-разомкнутых) и двух технологических входов (не имеют адреса) для подключения «сухих контактов» (нормально-замкнутых/нормально-разомкнутых) с контролем исправности входов;
  • управления двумя нереверсивными устройствами или одним реверсивным устройством с напряжением питания =12­­÷24В DC по командам от прибора ПАС300 с контролем исправности цепей управления на обрыв во всех состояниях и на КЗ в дежурном режиме.

МС322-24 имеет встроенные трехцветные светодиодные индикаторы для расширенного отображения состояния всех входов, устройств, а также самого модуля.

МС322-24 имеет встроенный изолятор короткого замыкания в интерфейсе С300.

МС322-24 позволяет управлять режимом работы световых табло по алгоритму:

  • Дежурный режим – горит непрерывно;
  • Режим Пожар – мигает с программируемой длительностью.

Основные функции:

Модуль обеспечивает:

  • Подключение и контроль состояния двух универсальных сигнальных шлейфов (пожарный тип1/тип2/тип3, НРК, НЗК) с контролем исправности на обрыв и короткое замыкание, а также передачу сигналов на прибор ПАС300. Для шлейфов предусмотрена возможность программирования соответствующих сигналов (Пожар, Внимание, Авария, нет сигнала), которые будут формироваться в системе С300 при срабатывании входа. Каждый сигнальный шлейф имеет адрес и может быть установлен в любую из 40 зон контроля в ПАС300 (по умолчанию зона 1);
  • Подключение и контроль состояния двух технологических нормально-замкнутых и/или нормально-разомкнутых входов типа «сухой контакт» с контролем исправности на обрыв и короткое замыкание и их передачу на прибор ПАС300. Для входов предусмотрена возможность программирования соответствующих сигналов (Авария источника питания, Авария устройства, Автоматика отключена, Ручной Пуск), которые будут формироваться в системе С300 при срабатывании входа. Технологические входы не имеют адресов и привязаны к адресу соответствующего устройства или входа питания;
  • Подключение двух нереверсивных исполнительных устройств или одного реверсивного устройства напряжением питания 12÷24В DС с контролем исправности цепей управления на обрыв во всех режимах и короткое замыкание в дежурном режиме;
  • По каждому выходу обеспечивается ток:
    • до 1 А импульсно или непрерывно любое время
    • до 5 А импульс длительностью до 3 сек или
    • до 3 импульсов длительностью 1 сек.
  • Каждый выход модуля имеет встроенную самовосстанавливающуюся защиту от короткого замыкания. При обнаружении короткого замыкания запуск устройства произведен не будет.

Полный контроль работоспособности обеспечивается как на физическом уровне (функция самотестирования в модуле), так и на программном уровне (постоянный опрос ПАС300).

Модуль занимает 4 адреса в адресном пространстве С300. Интерфейсная часть МС322-24 питается от прибора ПАС300.

Электронное программирование адреса (0 – заводская установка).

Восемь встроенных трехцветных светодиодных индикаторов помимо состояния сигнальных шлейфов (Сработка, Двойная Сработка и Дежурный режим) обеспечивают расширенную индикацию состояний самого модуля (неисправность, дублирование адресов, нулевой адрес, нет в базе ПАС300 и т.д.), а также состояние подключенного оборудования, что значительно упрощает процессы настройки и обслуживания системы С300 в целом.

Для каждого нереверсивного устройства помимо включения/отключения и возможности задания задержки пуска и остановки, предусмотрена возможность контролировать выход устройства на режим (поле Адрес подтверждающего датчика), а также опции по контролю цепи управления устройства (контроль на обрыв, контроль на КЗ, контроль на обрыв и КЗ, не контролировать) и состояние выхода в дежурном режиме:

  • Опция «Инверсный выход» не активна - выход выключен;
  • Опция «Инверсный выход» активна - выход включен

 

Подробнее

Для реверсивного устройства помимо возможности задания задержки пуска и остановки предусмотрена возможность выбора дежурного состояния (Реверсивный нормально открытый, Реверсивный нормально закрытый), а также опции по контролю цепи управления устройства (контроль на обрыв, контроль на КЗ, контроль на обрыв и КЗ, не контролировать).

Для каждого устройства можно запрограммировать следующие команды:

  • «Пуск», «ПускУ12» - включение устройства по истечении времени задержки на пуск
  • «½ Пуск» - включение устройства при поступлении двух и более команд «½ Пуск»
  • «Пуск с блокировкой» - включение устройства, если отсутствует сигнал блокировки
  • «Стоп» - выключение устройства по истечении времени задержки на останов
  • «½ Стоп» - выключение устройства при поступлении двух и более команд «½ Стоп»
  • «Отключить автоматику» - перевод устройства в режим «Автоматика устройства отключена»
  • «Включить автоматику» - отключение режима «Автоматика устройства отключена»

В качестве условий для формирования команд может использоваться срабатывание:

  • В любой из 40 зон данного ПАС300 или любого из 24 приборов ПАС300, объединённых в сеть
  • Любого шлейфа любого из приборов управления ПУ/ПУМ/ПУ-PL, объединённых в сеть
  • В любой из 64 групп ЦПИ, в каждую из которых можно добавлять зоны ПАС и/или шлейфы ПУ/ПУМ/ПУ-PL

Основные технические характеристики

Шлейфы Количество 2
Электропитание из вещателей 12÷27В, зависит от схемы подключения, нагрузки на шлейф
Действующее значение пульсаций не более 20 мВ
Ограничение тока через сработавший извещатель 20 мА
Сброс извещателей путем снятия напряжения питания на 10 секунд
Время интеграции шлейфов 300 мс
Контроль исправности шлейфов на обрыв и короткое замыкание
Тенхнологические входы Количество 2
Напряжение входов 3,3 В
Контроль исправности на обрыв и короткое замыкание
Максимальная длина линии 100 м
Назначение входов - авария питания;

- авария устройства 1 или 2;

- вкл/откл автоматику устройства 1 или 2;

- ручной пуск/стоп устройства 1 или 2.

Устройства Количество управляемых устройств 2 независимых или 1 реверсивное
Напряжение для устройств равно напряжению электропитания модуля
Ток контроля нагрузки 10 мА
Параметры каждого выхода 28 В/1,0 A – 28 Вт непрерывно,

28 В/5,0 А – 140 Вт до 3 сек

Контроль исправности цепей на обрыв и короткое замыкание во всех состояниях
Ток контроля исправности цепей не более 1,5 мА
Электропитание модуля 2 входа: =11,0÷28,4 В (≤60 Вт)
Интерфейс С300 Электропитание интерфейсной части от ПАС300 по интерфейсу С300
Напряжение интерфейса С300 от 11,5 до 28,0 В
Количество адресов в протоколе С300 4
Потребляемый ток от интерфейса не более 1,0 мА
Гальваническая развязка интерфейса есть
Изолятор короткого замыкания есть
Корпус Цвет корпуса светло-серый (RAL9002)
Масса, грамм не более 190
Габариты (ШхВхГ) 156х107х33 мм
Степень защиты оболочкой IP20
Крепление На саморезы или на DIN-рейку
Диапазон рабочих температур от минус 40 до +60°С
Допустимая относительная влажность до 93% при +40 °С
Температура транспортировки и хранения от минус 50 до +50°С
Средний срок службы не менее 10 лет
Датчик вскрытия корпуса есть